Automation Control
Product families
TYPESEnergy capacity Nm/cycleEnergy capacity Nm/hEffective weight min. kgEffective weight max. kg
A2X2EUSM3,6001,100,00025077,000
A2X4EUSM9,0001,350,00025082,000
A2X6EUSM13,5001,600,00026086,000
A2X8EUSM19,2001,900,00026090,000
A2X10EUSM23,7002,200,000320113,000

Heavy Industrial Shock Absorbers
A2X2EUSM

Deceleration of heavy loads and progressive adjustment

Adjustable
Energy capacity 3,600 Nm/cycle
Stroke 50 mm

Strong and adjustable: Also in ACE's range of units ares heavy duty industrial shock absorbers, which can be adjusted. The models from the A1 1/2 to A3 range, which weigh between 7.55 kg and 48 kg, are extremely robust, ready-to-install hydraulic machine elements with impressively high energy absorption levels and a wide range of damping rates.

Their special aspect is the flexibility,as all the absorbers can be adjusted using a socket on the absorber base and be perfectly adapted to the required data. The A models cover a range of effective loads from 0.3 kg to 204,000 kg and can absorb up to 44,000 Nm energy.
A2X2EUSM
Adjustable

Dimensions

A2X2EUSM
Stroke50 mm
C173 mm
D max.125 mm
E70 mm

Technical data

Energy capacity 3,600 Nm/cycle

Energy capacity 1,100,000 Nm/h

Energy capacity with air/oil tank 1,350,000 Nm/h

Effective weight min. 250 kg

Effective weight max. 77,000 kg

Return Force min. 210 N

Return Force max. 285 N

Return Time 0.25 s

Side Load Angle max. 3 °

Impact velocity range 0.1 m/s to 5 m/s. Other speeds on request.

Operating temperature range -12 °C to +66 °C. Other temperatures on request.

Mounting in any position

Positive stop External positive stops 2.5 mm to 3 mm before the end of stroke provided by the customer.

Adjustment Hard impact at the start of stroke, adjust the ring towards 9. Hard impact at the end of stroke, adjust the ring towards 0.

Material Outer body: steel corrosion-resistant coating; Piston rod: hard chrome plated steel; Rod end button: hardened steel and corrosion-resistant coating; Return spring: zinc plated steel

Damping medium Automatic Transmission Fluid (ATF)

Note

For emergency use only applications and for continous use it is possible to exceed the published max. capacity ratings. In this case, please consult ACE.

Safety information

External materials in the surrounding area can attack the seal components and lead to a shorter service life. Please contact ACE for appropriate solution suggestions. Do not paint the shock absorbers due to heat emission.

On request

Special oils, nickel-plated, increased corrosion protection or other special options are available on request.

General information
×

ACE Controls Inc. | Login